Before the bearings come out
Find what the high readings have in common
The bearing order for cooling-water pump 3 looks straightforward. The motor-top vibration was low through the cooler months, then high in March, about half as high in April and high again in May. The work request says replace the motor bearings.
There is a useful check before that order goes ahead. This vertical pump has a variable-frequency drive (VFD) holding the header pressure, so a monthly visit need not catch it at the same speed. The pump and its readings are a calculated example, not a plant record; the resonance pattern is documented in pump guidance.
Before a bearing set is ordered, add one column to the route record: the drive speed at the moment of each reading. In this record, the four highest readings were all taken between 1,300 and 1,335 rpm, on afternoons when cooling demand pushed the drive up. Every lower reading came at a lower speed, between 1,060 and 1,240 rpm.
That clustering changes the investigation. A repeatable peak in one speed band supports checking for resonance; it does not clear the bearings. Bearing condition still needs its own evidence, compared at similar speed and duty.
How resonance works
Why one speed can make the structure shake
Every machine pushes on its structure as it turns, because no rotor is perfectly balanced and no shaft line is perfectly aligned. A pump rotordynamics tutorial from the Texas A&M Turbomachinery and Pump Symposium names the forcing frequencies seen most often in pumps: running speed (1×), twice running speed (2×) and vane pass, which is the number of impeller vanes times running speed.
The structure has natural frequencies of its own, the rates at which it rings if you rap it. When a forcing frequency lands on one, each push arrives just as the motion from the last one comes round. The motion builds until damping soaks up as much energy as each push adds. The tutorial puts the usual amplification at 2 to 25 times the movement the same force would cause if it were steady.
A fixed-speed pump can be designed to keep clear of its natural frequencies. On a VFD, every forcing frequency sweeps across a range. The DOE guide to variable speed pumping, written with the Hydraulic Institute and Europump, says this greatly increases the chance of resonance within the operating range, and that vertical pumps are more prone to it than horizontal ones because their natural frequencies are lower.
On a vertical pump, look first at the tall discharge head and motor above the base, which can sway together like a reed: the Hydraulic Institute's pump dynamics guideline calls this the reed frequency. The access windows cut into the discharge head can make it stiffer in one direction than the other, so the frequency in line with the discharge pipe can differ from the one across it, as a Hydraulic Institute pump FAQ explains.
The force has not grown. The structure's response has, and the tutorial warns that resonant motion often damages bearings, seals and running clearances. New bearings fitted into the same structure would meet the same motion.
Same readings, new order
Same readings, a different pattern
Plot the same twelve readings against drive speed. The calculation assumes a natural frequency of 1,320 rpm (22 Hz), 5% damping and unchanged unbalance. It plots vibration velocity at running speed; nothing wears. The four-pole motor stays below 1,500 rpm at the drive's 50 Hz maximum.
ONE RECORD, TWO VIEWS
Change the axis. See the pattern.
Twelve readings, now ordered by speed. The pale amber strip spans the four high visits, 1,300 to 1,335 rpm; it is not a prescribed operating or skip-speed band. Dashed sections lie outside the measured 1,060 to 1,335 rpm span.
The readings now follow one curve, and similar speeds months apart agree. Some rise with speed is expected: SKF's spectrum analysis guide lists that among the signs of unbalance. Here, the sharp climb near 1,320 rpm deserves a closer look.
The model also leaves out the scatter of real readings, and the curve is dashed where no reading supports it. No visit fell above 1,335 rpm, so the descending tail beyond that speed is calculated, not measured. A planned test has to supply it.
This works only if speed is in the record, ideally from a tachometer. The drive's output frequency is second best: an induction motor runs slightly below its synchronous speed, and further below it under load, as the US Department of Energy's motor fact sheet explains.
Record direction too. Take both horizontal directions at the motor top and mark the one in line with the discharge; a reading much higher in one direction fits the directional stiffness described above.
Speed also moves a pump's flow and head, so a hydraulic problem can change with speed too. Our field note on where the pump is running covers those checks.
Confirming the band
Give the suspected resonance a proper test
Test the suspected band under an agreed plan. ISO 13373-2 includes refining a diagnosis by changing operating conditions. Both tests below need a qualified analyst (ISO 18436-2), site permits and operating-team approval.
A slow speed sweep. In a low-demand window, the operating team moves the pump slowly through its approved speed range, or the analyst records through a planned stop or start. At each speed the analyst logs the amplitude and phase of the running-speed (1×) component in both directions at the motor top. Keep the sweep moving through the band rather than holding the pump in it.
Phase needs a once-per-turn reference from the shaft, as Prosig explains; a common choice is an optical or laser tachometer reading a reflective mark on the shaft, as PCB Piezotronics describes.
AMPLITUDE AND PHASE, TOGETHER
The peak is only half the story.
Velocity amplitude and displacement phase for the same unbalance on two structures. Solid: natural frequency 1,320 rpm. Dashed: equally stiff and lighter, with natural frequency 2,400 rpm. The phase change is about 146 degrees versus 3 degrees.
The lower chart shows displacement phase lag, not velocity phase. Its 90-degree crossing marks the natural frequency. A velocity signal is shifted by a constant 90 degrees relative to displacement, so the size of the phase change across speeds stays the same.
Sensor position and the shaft mark add an offset to a field phase reading, another reason to compare the change rather than an absolute value. The same SKF guide gives the phase values in its fault rules a tolerance of about 30 degrees either way, for mechanical variance. The change of about 146 degrees in the calculated sweep is far outside that.
An impact test. With the pump stopped and isolated under the site's permit, the analyst strikes the structure, often with an instrumented hammer, and records how it rings. Natural frequencies show up as peaks in the response. ISO 7626-5 notes that even a quick impact test gives approximate natural frequencies.
Test the installed pump, because water in the column, the pipework and the foundation all affect its natural frequencies. A clean vibration test at a single speed is no proof either: the DOE guide notes that a pump meant for variable speed is often tested at only one speed.
A sweep shows how the structure behaves while running; an impact test finds its natural frequencies at rest. A practitioner article summarised on Emerson's blog advises at least two tests before anything is changed.
What each pattern points to
Resonance is the leading explanation. Check which forcing frequency (1×, 2× or vane pass) meets it.
Check unbalance and alignment, which the tutorial puts first in its troubleshooting order. Review duty and measurement settings too; this pattern alone does not settle the cause.
The machine or the measurement has changed. Check the measurement, then investigate, bearings included.
Evidence of bearing damage, whatever the speed pattern. Our vibration alarm field note covers how to qualify it.
Getting out of the band
Choose the fix after confirming the band
Once the band is confirmed, there are two common ways out of it. Neither is a bearing change.
Change the structure. Added stiffness raises a natural frequency; added mass lowers it. For vertical pumps the Hydraulic Institute FAQ lists changes to the discharge head windows or shell, ribs or gussets, the structural height, the flanged joints or the driver.
Keep the natural frequency a clear margin from the whole operating speed range, not just the usual speed. Check 2× and vane pass too, because a natural frequency moved away from 1× can land on another forcing frequency. This is work for the pump maker or a structural specialist, followed by a repeat sweep.
Keep the drive out of the band. ABB's ACS880 firmware manual describes a critical speeds function for avoiding mechanical resonance, and SEW-EURODRIVE's documentation explains how its skip frequency band behaves: if the requested speed falls inside the band, the drive holds at its upper or lower edge, depending on the previous setpoint, and crosses the band on its normal ramp.
The pressure control then has to live with a gap in the pump's range. Agree the band with operations, keep a margin either side of the measured peak and confirm that the remaining range still meets demand. A skip band can be a permanent setting, or a stopgap while a structural change is designed.
If the bearing evidence also points to damage, change the bearings and deal with the band as well. Otherwise the new set goes straight back into the resonance.
Worked example
Back to the bearing work request
Back to cooling-water pump 3. The planner has the route history, the drive log and one envelope spectrum, a processed reading that SKF's guide describes as bringing out the repeated impacts of a rolling-bearing defect.
The four highest readings, 1.7 to 2.8 times those in the months between, were all taken at 1,300 to 1,335 rpm.
March at 1,320 rpm and September at 1,310 rpm agree within 3%, so there is no upward drift at matched speed.
The high component is at 1× running speed. The envelope spectrum shows no pattern at the calculated bearing frequencies.
No speed sweep with phase or impact test yet, and most visits measured one direction only.
Use in the field
Six checks to keep with the bearing order
- SpeedShaft speed, or at least the drive output frequency, with every reading.
- DirectionBoth horizontal directions at the motor top, with the one in line with the discharge marked.
- Matched comparisonReadings at the same speed compared before anyone calls a trend.
- FrequencyWhether the high component sits at 1×, 2×, vane pass or a calculated bearing frequency.
- Confirming testA slow sweep with phase and, where possible, an impact test, run by a qualified analyst.
- Fix and verifyA structural change or an agreed skip band, followed by a repeat test.
Technical sources
Sources behind the field method
These references inform the method in this field note. Standards links point to public catalogue pages, and only their public abstracts or contents pages were read. They do not imply ConditionCore certification or conformity with a particular standard.
References
- Variable Speed Pumping: A Guide to Successful Applications, Executive SummaryUS Department of Energy, Hydraulic Institute and Europump. DOE/GO-102004-1913, May 2004. Structural resonance and rotor dynamics among the potential drawbacks of variable speed drives, pages 10 to 11.
- "Avoiding Vibration in Vertical Pumps"Hydraulic Institute Pump FAQ. Pumps & Systems, 7 February 2022. Flexible above-base structures, directional natural frequencies, separation across the speed range and structural changes.
- ANSI/HI 9.6.8 Rotodynamic Pumps: Guideline for Dynamics of Pumping MachineryHydraulic Institute. 2021 reaffirmation of the 2014 edition. Product page and 2014 table of contents read; the standard itself was not.
- An End-User's Guide to Centrifugal Pump RotordynamicsMarscher, W. D. Texas A&M Turbomachinery and Pump Symposium, 2018; Turbomachinery Laboratory, Texas A&M Engineering Experiment Station. Forcing frequencies, resonance, amplification, phase, troubleshooting order and vertical pump modelling.
- ACS880 Primary Control Program (AINLX) Firmware ManualABB. 3AUA0000085967 Rev Y, effective 7 March 2024. Section "Critical speeds/frequencies" and parameters 22.51 to 22.57.
- MOVITRAC LTP-B documentation, "P2-09/P2-10 Skip frequency/skip frequency band"SEW-EURODRIVE. Edition 10/23.
- ISO 7626-5:2019ISO. Mechanical mobility measured with impact excitation. Public abstract only.
- ISO 13373-2:2016ISO. Processing, analysis and presentation of vibration data. Public abstract only.
- ISO 18436-2:2014ISO. Qualification and assessment of vibration personnel. Public abstract only. ISO lists a third edition at final draft (FDIS) stage.
- "Vibration Monitoring Phase Measurement and the Tacho Signal"Mercer, C. Prosig, 4 March 2008.
- "Spotting and Fixing Resonance in Plant Equipment"Cahill, J. Emerson Automation Experts, 29 January 2010, summarising guidance by Alain Pellegrino of Laurentide Controls.
- Spectrum Analysis: The Key Features of Analyzing SpectraMais, J. SKF, CM5118 EN, May 2002. Characteristics of unbalance, phase tolerance notes and acceleration enveloping for bearing defects.
- Determining Electric Motor Load and EfficiencyUS Department of Energy, Motor Challenge. Fact sheet DOE/GO-10097-517. The Slip Method.
- "ICP Speed Sensors"PCB Piezotronics. Application page for The Modal Shop LaserTach LT2. Laser tachometer with a retroreflective target as a speed and phase reference.
Back at the work request
Send the speeds with the readings.
Back at the work request, the useful next step is no longer simply another bearing set. It is to establish whether the high readings follow a structural response, a bearing problem, a hydraulic condition or a combination. Sorting by speed has narrowed the question; the planned tests still have to answer it.
If a variable-speed machine on your site reads high in one speed band, send ConditionCore the route readings with their speeds and directions, the spectra and drive logs you have, and any sweep or impact data. The vibration analysis page lists resonance among the patterns the method can reveal, judged from amplitude and phase change across speed.
The review returns what is usable, the leading explanation and its alternatives, and the next check that would separate them. Your team or your analyst runs any test on site.
Review a machine with ConditionCore